| * measurementMgrSM.c |
| * |
| * Copyright(c) 1998 - 2010 Texas Instruments. All rights reserved. |
| * All rights reserved. |
| * |
| * Redistribution and use in source and binary forms, with or without |
| * modification, are permitted provided that the following conditions |
| * are met: |
| * |
| * * Redistributions of source code must retain the above copyright |
| * notice, this list of conditions and the following disclaimer. |
| * * Redistributions in binary form must reproduce the above copyright |
| * notice, this list of conditions and the following disclaimer in |
| * the documentation and/or other materials provided with the |
| * distribution. |
| * * Neither the name Texas Instruments nor the names of its |
| * contributors may be used to endorse or promote products derived |
| * from this software without specific prior written permission. |
| * |
| * THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS |
| * "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT |
| * LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR |
| * A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT |
| * OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, |
| * SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT |
| * LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, |
| * DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY |
| * THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT |
| * (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE |
| * OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. |
| */ |
| |
| |
| /**************************************************************************/ |
| /* */ |
| /* MODULE: measurementMgrSM.c */ |
| /* PURPOSE: Measurement Manager State Machine module interface. */ |
| /* */ |
| /**************************************************************************/ |
| |
| |
| |
| #define __FILE_ID__ FILE_ID_2 |
| #include "measurementMgrSM.h" |
| #include "measurementMgr.h" |
| #include "802_11Defs.h" |
| #ifdef XCC_MODULE_INCLUDED |
| #include "XCCMngr.h" |
| #include "XCCRMMngr.h" |
| #endif |
| #include "spectrumMngmntMgr.h" |
| #include "siteMgrApi.h" |
| #include "MacServices_api.h" |
| #include "regulatoryDomainApi.h" |
| #include "TWDriver.h" |
| #include "timer.h" |
| #include "sme.h" |
| |
| |
| char * measurementMgr_stateDesc[MEASUREMENTMGR_NUM_STATES] = |
| { |
| "STATE_IDLE", |
| "STATE_PROCESSING_REQUEST", |
| "STATE_WAITING_FOR_SCR", |
| "STATE_MEASURING" |
| }; |
| |
| |
| char * measurementMgr_eventDesc[MEASUREMENTMGR_NUM_EVENTS] = |
| { |
| "EVENT_CONNECTED", |
| "EVENT_DISCONNECTED", |
| "EVENT_ENABLE", |
| "EVENT_DISABLE", |
| "EVENT_FRAME_RECV", |
| "EVENT_SEND_REPORT", |
| "EVENT_REQUEST_SCR", |
| "EVENT_SCR_WAIT", |
| "EVENT_SCR_RUN", |
| "EVENT_ABORT", |
| "EVENT_COMPLETE", |
| "EVENT_FW_RESET" |
| }; |
| |
| |
| |
| |
| /********************************************************************************/ |
| /* MeasurementMgr SM Action Prototypes */ |
| /********************************************************************************/ |
| |
| static TI_STATUS measurementMgrSM_acUnexpected(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acNop(void * pData); |
| |
| |
| static TI_STATUS measurementMgrSM_acConnected(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acDisconnected_fromIdle(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acEnable(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acDisable_fromIdle(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acFrameReceived_fromIdle(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acSendReportAndCleanObj(void * pData); |
| |
| |
| static TI_STATUS measurementMgrSM_acDisconnected_fromProcessingRequest(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acDisable_fromProcessingRequest(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acFrameReceived_fromProcessingRequest(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acAbort_fromProcessingRequest(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acRequestSCR(void * pData); |
| |
| |
| static TI_STATUS measurementMgrSM_acDisconnected_fromWaitForSCR(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acDisable_fromWaitForSCR(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acFrameReceived_fromWaitForSCR(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acAbort_fromWaitForSCR(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acStartMeasurement(void * pData); |
| |
| |
| static TI_STATUS measurementMgrSM_acDisconnected_fromMeasuring(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acDisable_fromMeasuring(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acFrameReceived_fromMeasuring(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acAbort_fromMeasuring(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acMeasurementComplete(void * pData); |
| |
| static TI_STATUS measurementMgrSM_acFirmwareReset(void * pData); |
| |
| |
| |
| |
| |
| |
| |
| |
| /********************************************************************************/ |
| /* Internal Functions Prototypes */ |
| /********************************************************************************/ |
| |
| static void measurementMgrSM_resetParams(measurementMgr_t * pMeasurementMgr); |
| |
| static void measurementMgrSM_uponActivationDelayTimeout (TI_HANDLE hMeasurementMgr, TI_BOOL bTwdInitOccured); |
| |
| |
| |
| |
| |
| |
| |
| /********************************************************************************/ |
| /* MeasurementMgr SM General Use Functions */ |
| /********************************************************************************/ |
| |
| |
| /** |
| * Configures the Measurement Manager State Machine. |
| * |
| * @param hMeasurementMgr A handle to the Measurement Manager module. |
| * |
| * @date 01-Jan-2006 |
| */ |
| TI_STATUS measurementMgrSM_config(TI_HANDLE hMeasurementMgr) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) hMeasurementMgr; |
| TI_STATUS status; |
| |
| /* MeasurementMgr State Machine matrix */ |
| fsm_actionCell_t measurementMgr_matrix[MEASUREMENTMGR_NUM_STATES][MEASUREMENTMGR_NUM_EVENTS] = |
| { |
| /* next state and actions for STATE_IDLE state */ |
| { |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acConnected}, /* CONNECTED */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acDisconnected_fromIdle}, /* DISCONNECTED */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acEnable}, /* ENABLE */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acDisable_fromIdle}, /* DISABLE */ |
| {MEASUREMENTMGR_STATE_PROCESSING_REQUEST, measurementMgrSM_acFrameReceived_fromIdle}, /* FRAME_RECV */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acSendReportAndCleanObj}, /* SEND_REPORT */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acUnexpected}, /* REQUEST_SCR */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acUnexpected}, /* SCR_WAIT */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acUnexpected}, /* SCR_RUN */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acUnexpected}, /* ABORT */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acUnexpected}, /* COMPLETE */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acUnexpected} /* FW_RESET */ |
| }, |
| |
| /* next state and actions for STATE_PROCESSING_REQUEST state */ |
| { |
| {MEASUREMENTMGR_STATE_PROCESSING_REQUEST, measurementMgrSM_acUnexpected}, /* CONNECTED */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acDisconnected_fromProcessingRequest}, /* DISCONNECTED */ |
| {MEASUREMENTMGR_STATE_PROCESSING_REQUEST, measurementMgrSM_acNop}, /* ENABLE */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acDisable_fromProcessingRequest}, /* DISABLE */ |
| {MEASUREMENTMGR_STATE_PROCESSING_REQUEST, measurementMgrSM_acFrameReceived_fromProcessingRequest}, /* FRAME_RECV */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acSendReportAndCleanObj}, /* SEND_REPORT */ |
| {MEASUREMENTMGR_STATE_WAITING_FOR_SCR, measurementMgrSM_acRequestSCR}, /* REQUEST_SCR */ |
| {MEASUREMENTMGR_STATE_PROCESSING_REQUEST, measurementMgrSM_acUnexpected}, /* SCR_WAIT */ |
| {MEASUREMENTMGR_STATE_PROCESSING_REQUEST, measurementMgrSM_acUnexpected}, /* SCR_RUN */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acAbort_fromProcessingRequest}, /* ABORT */ |
| {MEASUREMENTMGR_STATE_PROCESSING_REQUEST, measurementMgrSM_acUnexpected}, /* COMPLETE */ |
| {MEASUREMENTMGR_STATE_PROCESSING_REQUEST, measurementMgrSM_acUnexpected} /* FW_RESET */ |
| }, |
| |
| /* next state and actions for STATE_WAITING_FOR_SCR state */ |
| { |
| {MEASUREMENTMGR_STATE_WAITING_FOR_SCR, measurementMgrSM_acUnexpected}, /* CONNECTED */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acDisconnected_fromWaitForSCR}, /* DISCONNECTED */ |
| {MEASUREMENTMGR_STATE_WAITING_FOR_SCR, measurementMgrSM_acNop}, /* ENABLE */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acDisable_fromWaitForSCR}, /* DISABLE */ |
| {MEASUREMENTMGR_STATE_PROCESSING_REQUEST, measurementMgrSM_acFrameReceived_fromWaitForSCR}, /* FRAME_RECV */ |
| {MEASUREMENTMGR_STATE_WAITING_FOR_SCR, measurementMgrSM_acUnexpected}, /* SEND_REPORT */ |
| {MEASUREMENTMGR_STATE_WAITING_FOR_SCR, measurementMgrSM_acUnexpected}, /* REQUEST_SCR */ |
| {MEASUREMENTMGR_STATE_WAITING_FOR_SCR, measurementMgrSM_acNop}, /* SCR_WAIT */ |
| {MEASUREMENTMGR_STATE_MEASURING, measurementMgrSM_acStartMeasurement}, /* SCR_RUN */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acAbort_fromWaitForSCR}, /* ABORT */ |
| {MEASUREMENTMGR_STATE_WAITING_FOR_SCR, measurementMgrSM_acUnexpected}, /* COMPLETE */ |
| {MEASUREMENTMGR_STATE_WAITING_FOR_SCR, measurementMgrSM_acUnexpected} /* FW_RESET */ |
| }, |
| |
| /* next state and actions for STATE_MEASURING state */ |
| { |
| {MEASUREMENTMGR_STATE_MEASURING, measurementMgrSM_acUnexpected}, /* CONNECTED */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acDisconnected_fromMeasuring}, /* DISCONNECTED */ |
| {MEASUREMENTMGR_STATE_MEASURING, measurementMgrSM_acNop}, /* ENABLE */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acDisable_fromMeasuring}, /* DISABLE */ |
| {MEASUREMENTMGR_STATE_PROCESSING_REQUEST, measurementMgrSM_acFrameReceived_fromMeasuring}, /* FRAME_RECV */ |
| {MEASUREMENTMGR_STATE_MEASURING, measurementMgrSM_acUnexpected}, /* SEND_REPORT */ |
| {MEASUREMENTMGR_STATE_MEASURING, measurementMgrSM_acUnexpected}, /* REQUEST_SCR */ |
| {MEASUREMENTMGR_STATE_MEASURING, measurementMgrSM_acUnexpected}, /* SCR_WAIT */ |
| {MEASUREMENTMGR_STATE_MEASURING, measurementMgrSM_acUnexpected}, /* SCR_RUN */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acAbort_fromMeasuring}, /* ABORT */ |
| {MEASUREMENTMGR_STATE_PROCESSING_REQUEST, measurementMgrSM_acMeasurementComplete}, /* COMPLETE */ |
| {MEASUREMENTMGR_STATE_IDLE, measurementMgrSM_acFirmwareReset} /* FW_RESET */ |
| } |
| |
| }; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Configured MeasurementMgr state machine\n"); |
| |
| status = fsm_Config(pMeasurementMgr->pMeasurementMgrSm, |
| &measurementMgr_matrix[0][0], |
| MEASUREMENTMGR_NUM_STATES, |
| MEASUREMENTMGR_NUM_EVENTS, |
| measurementMgrSM_event, pMeasurementMgr->hOs); |
| |
| return status; |
| } |
| |
| |
| |
| /** |
| * Raises a State Machine event in the Measurement Manager SM. |
| * |
| * @param currentState A point to the member holding the SM's current state. |
| * @param event The event we want to raise. |
| * @param hMeasurementMgr A handle to the Measurement Manager module. |
| * |
| * @date 05-Jan-2006 |
| */ |
| TI_STATUS measurementMgrSM_event(TI_UINT8 * currentState, TI_UINT8 event, TI_HANDLE hMeasurementMgr) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) hMeasurementMgr; |
| TI_STATUS status; |
| TI_UINT8 nextState; |
| |
| status = fsm_GetNextState(pMeasurementMgr->pMeasurementMgrSm, |
| *currentState, event, &nextState); |
| |
| if (status != TI_OK) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": State machine error, failed getting next state\n"); |
| |
| return(TI_NOK); |
| } |
| |
| TRACE3(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, "measurementMgrSM_event: <currentState = %d, event = %d> --> nextState = %d\n", currentState, event, nextState); |
| |
| status = fsm_Event(pMeasurementMgr->pMeasurementMgrSm, currentState, event, (void *) pMeasurementMgr); |
| |
| return status; |
| } |
| |
| |
| |
| |
| |
| |
| |
| /********************************************************************************/ |
| /* MeasurementMgr SM Action Functions */ |
| /********************************************************************************/ |
| |
| |
| /********************************************************************************/ |
| /* IDLE State Actions */ |
| /********************************************************************************/ |
| |
| /** |
| * Performs the required action when the Measurement Manager module has |
| * been advised that the station has connected to an AP. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acConnected(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| paramInfo_t param; |
| |
| #ifdef XCC_MODULE_INCLUDED |
| iappParsingRegistrationTable_t iappParsingRegistration; |
| #endif |
| |
| /* do nothing if we're already in connected mode */ |
| if (pMeasurementMgr->Connected) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Connected flag already set\n"); |
| |
| return TI_OK; |
| } |
| |
| pMeasurementMgr->Connected = TI_TRUE; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Connected flag has been set\n"); |
| |
| /* upon connection to a new AP set the measurment scan flag to FALSE */ |
| pMeasurementMgr->bMeasurementScanExecuted = TI_FALSE; |
| |
| /* get the current serving channel */ |
| param.paramType = SITE_MGR_CURRENT_CHANNEL_PARAM; |
| siteMgr_getParam(pMeasurementMgr->hSiteMgr, ¶m); |
| pMeasurementMgr->servingChannelID = param.content.siteMgrCurrentChannel; |
| |
| #ifdef XCC_MODULE_INCLUDED |
| if(pMeasurementMgr->Mode == MSR_MODE_XCC) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": MeasurementMgr set to XCC mode\n"); |
| |
| if(pMeasurementMgr->isModuleRegistered == TI_FALSE) |
| { |
| /* Registering to the XCCMngr */ |
| iappParsingRegistration.handler = pMeasurementMgr; |
| iappParsingRegistration.iappParsingRegistrationProcedure = measurementMgr_XCCParse; |
| |
| if (XCCMngr_registerForRecvIappPacket(pMeasurementMgr->hXCCMngr, |
| iappParsingRegistration, IAPP_RADIO_MEASUREMENT) != TI_OK) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_WARNING, ": Could not register to receive IAPP packets\n"); |
| |
| return TI_NOK; |
| } |
| |
| pMeasurementMgr->isModuleRegistered = TI_TRUE; |
| } |
| |
| pMeasurementMgr->parserFrameReq = measurementMgr_XCCParseFrameReq; |
| pMeasurementMgr->isTypeValid = measurementMgr_XCCIsTypeValid; |
| pMeasurementMgr->buildReport = measurementMgr_XCCBuildReport; |
| pMeasurementMgr->buildRejectReport = measurementMgr_XCCBuildRejectReport; |
| pMeasurementMgr->sendReportAndCleanObj = measurementMgr_XCCSendReportAndCleanObject; |
| requestHandler_setRequestParserFunction(pMeasurementMgr->hRequestH, |
| measurementMgr_XCCParseRequestIEHdr); |
| } |
| else |
| #endif |
| { |
| if(pMeasurementMgr->Mode == MSR_MODE_SPECTRUM_MANAGEMENT) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": MeasurementMgr set to Spectrum Management mode\n"); |
| |
| /* NOTE: These 5 functions need to be corrected to fit the 802.11h standered */ |
| pMeasurementMgr->parserFrameReq = measurementMgr_dot11hParseFrameReq; |
| pMeasurementMgr->isTypeValid = measurementMgr_dot11hIsTypeValid; |
| pMeasurementMgr->buildReport = measurementMgr_dot11hBuildReport; |
| pMeasurementMgr->buildRejectReport = measurementMgr_dot11hBuildRejectReport; |
| pMeasurementMgr->sendReportAndCleanObj = measurementMgr_dot11hSendReportAndCleanObject; |
| requestHandler_setRequestParserFunction(pMeasurementMgr->hRequestH, |
| measurementMgr_dot11hParseRequestIEHdr); |
| |
| } |
| } |
| |
| return TI_OK; |
| } |
| |
| |
| |
| /** |
| * Called when the Measurement Manager has been advised that the station |
| * has disconnected from the AP. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acDisconnected_fromIdle(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Connected flag unset\n"); |
| |
| pMeasurementMgr->Connected = TI_FALSE; |
| |
| return TI_OK; |
| } |
| |
| |
| |
| /** |
| * Called when the Measurement Manager is enabled. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acEnable(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Measurement Manager has been enabled\n"); |
| |
| pMeasurementMgr->Enabled = TI_TRUE; |
| |
| return TI_OK; |
| } |
| |
| |
| |
| /** |
| * Called when the Measurement Manager is disabled. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acDisable_fromIdle(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Measurement Manager has been disabled\n"); |
| |
| pMeasurementMgr->Enabled = TI_FALSE; |
| |
| return TI_OK; |
| } |
| |
| |
| |
| /** |
| * Called when the SM is in an idle state and we receive a new measurement frame. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acFrameReceived_fromIdle(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| TI_UINT16 activationDelay; |
| TI_STATUS status; |
| paramInfo_t param; |
| TI_UINT16 tbtt; |
| |
| /* handle frame request only if we're connected and measurement is enabled */ |
| if (pMeasurementMgr->Connected == TI_FALSE || |
| pMeasurementMgr->Enabled == TI_FALSE) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_ERROR, ": Frame received while SM is in disconnected/disabled state\n"); |
| |
| return measurementMgrSM_event((TI_UINT8 *) &(pMeasurementMgr->currentState), |
| MEASUREMENTMGR_EVENT_ABORT, pMeasurementMgr); |
| } |
| |
| /* Setting the frame Type */ |
| pMeasurementMgr->currentFrameType = pMeasurementMgr->newFrameRequest.frameType; |
| |
| TRACE1(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Frame Type = %d\n", pMeasurementMgr->currentFrameType); |
| |
| /* Getting the Beacon Interval from the Site Mgr */ |
| param.paramType = SITE_MGR_BEACON_INTERVAL_PARAM; |
| status = siteMgr_getParam(pMeasurementMgr->hSiteMgr, ¶m); |
| if (status != TI_OK) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_ERROR, ": Failed to retrieve beacon interval - not connected?\n"); |
| |
| return measurementMgrSM_event((TI_UINT8 *) &(pMeasurementMgr->currentState), |
| MEASUREMENTMGR_EVENT_ABORT, pMeasurementMgr); |
| } |
| |
| /* converting beacon interval to msec */ |
| tbtt = (param.content.beaconInterval * 1024) / 1000; /* from TU to msec */ |
| |
| /* Initializing Activation Delay Time */ |
| activationDelay = pMeasurementMgr->newFrameRequest.hdr->activatioDelay; |
| activationDelay *= tbtt; |
| /* Adding the Measurement Offset to the activation delay */ |
| activationDelay += pMeasurementMgr->newFrameRequest.hdr->measurementOffset; |
| |
| /* Inserting all received measurement requests into the queue */ |
| status = requestHandler_insertRequests(pMeasurementMgr->hRequestH, |
| pMeasurementMgr->Mode, |
| pMeasurementMgr->newFrameRequest); |
| |
| /* Clean New Frame Params */ |
| os_memoryZero(pMeasurementMgr->hOs, &pMeasurementMgr->newFrameRequest, |
| sizeof(TMeasurementFrameRequest)); |
| |
| if (status != TI_OK) |
| { |
| pMeasurementMgr->currentFrameType = MSR_FRAME_TYPE_NO_ACTIVE; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_ERROR, ": Could not insert request into the queue\n"); |
| |
| return measurementMgrSM_event((TI_UINT8 *) &(pMeasurementMgr->currentState), |
| MEASUREMENTMGR_EVENT_ABORT, pMeasurementMgr); |
| } |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": New frame has been inserted into the queue\n"); |
| |
| /* If frame type isn't Unicast add to Activation Delay a random delay */ |
| if ((pMeasurementMgr->currentFrameType != MSR_FRAME_TYPE_UNICAST) && (activationDelay > 0)) |
| { |
| activationDelay += ((os_timeStampMs(pMeasurementMgr->hOs) % MSR_ACTIVATION_DELAY_RANDOM) |
| + MSR_ACTIVATION_DELAY_OFFSET); |
| } |
| |
| TRACE1(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Activation Delay in ms = %d\n", activationDelay); |
| |
| if (activationDelay > 0) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Going to wait for activation delay timer callback\n"); |
| |
| /* Starting the Activation Delay Timer */ |
| tmr_StartTimer (pMeasurementMgr->hActivationDelayTimer, |
| measurementMgrSM_uponActivationDelayTimeout, |
| (TI_HANDLE)pMeasurementMgr, |
| activationDelay, |
| TI_FALSE); |
| |
| return TI_OK; |
| } |
| else |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Activating the next request immediately without waiting for callback\n"); |
| |
| /* Calling to schedule the first waiting request */ |
| return measurementMgr_activateNextRequest(pData); |
| } |
| } |
| |
| |
| |
| |
| |
| /********************************************************************************/ |
| /* PROCESSING_REQUEST State Actions */ |
| /********************************************************************************/ |
| |
| /** |
| * Called when the station disconnects from the AP while processing |
| * a measurement request. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acDisconnected_fromProcessingRequest(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| /* Stopping the activationDelay Timer */ |
| tmr_StopTimer (pMeasurementMgr->hActivationDelayTimer); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| pMeasurementMgr->Connected = TI_FALSE; |
| |
| return TI_OK; |
| } |
| |
| |
| |
| /** |
| * Called when the Measurement Manager module has been disable while |
| * processing a measurement request. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acDisable_fromProcessingRequest(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| /* Stopping the activationDelay Timer */ |
| tmr_StopTimer (pMeasurementMgr->hActivationDelayTimer); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| pMeasurementMgr->Enabled = TI_FALSE; |
| |
| return TI_OK; |
| } |
| |
| |
| |
| /** |
| * Called when a frame has been received while we are processing another frame. |
| * In this case the older frame is discarded and the new frame is processed. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acFrameReceived_fromProcessingRequest(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| /* Stopping the activationDelay Timer */ |
| tmr_StopTimer (pMeasurementMgr->hActivationDelayTimer); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| /* Process New Frame */ |
| return measurementMgrSM_acFrameReceived_fromIdle(pData); |
| } |
| |
| |
| |
| /** |
| * Sends measurement reports to the AP and cleans up the module. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acSendReportAndCleanObj(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Sending pending reports and cleaning up...\n"); |
| |
| return pMeasurementMgr->sendReportAndCleanObj(pData); |
| } |
| |
| |
| |
| /** |
| * Called when for some reason we abort while processing a request. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acAbort_fromProcessingRequest(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Entered\n"); |
| |
| /* Stopping the activationDelay Timer */ |
| tmr_StopTimer (pMeasurementMgr->hActivationDelayTimer); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| return TI_OK; |
| } |
| |
| |
| |
| /** |
| * Called when we finished processing a request and want to request the SCR. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acRequestSCR(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| EScrClientRequestStatus scrStatus; |
| EScePendReason scrPendReason; |
| |
| /* Request the channel */ |
| scrStatus = scr_clientRequest(pMeasurementMgr->hScr, SCR_CID_XCC_MEASURE, |
| SCR_RESOURCE_SERVING_CHANNEL, &scrPendReason); |
| |
| if (scrStatus == SCR_CRS_RUN) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Received RUN response from SCR\n"); |
| |
| /* The channel is allocated for the measurement */ |
| return measurementMgrSM_event((TI_UINT8 *) &(pMeasurementMgr->currentState), |
| MEASUREMENTMGR_EVENT_SCR_RUN, pMeasurementMgr); |
| } |
| else if ((scrStatus == SCR_CRS_PEND) && (scrPendReason == SCR_PR_DIFFERENT_GROUP_RUNNING)) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Received PEND/DIFFGROUP response from SCR\n"); |
| |
| /* No need to wait for the channel allocation */ |
| return measurementMgrSM_event((TI_UINT8 *) &(pMeasurementMgr->currentState), |
| MEASUREMENTMGR_EVENT_ABORT, pMeasurementMgr); |
| } |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Going to wait for SCR callback...\n"); |
| |
| /* In all other cases wait for the callback function to be called */ |
| return TI_OK; |
| } |
| |
| |
| |
| |
| |
| /********************************************************************************/ |
| /* WAIT_FOR_SCR State Actions */ |
| /********************************************************************************/ |
| |
| |
| /** |
| * Called if the station disconnects from the AP while waiting for a |
| * response from the SCR. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acDisconnected_fromWaitForSCR(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| setDefaultProbeReqTemplate (pMeasurementMgr->hSiteMgr); |
| |
| /* Release the SCR */ |
| scr_clientComplete(pMeasurementMgr->hScr, SCR_CID_XCC_MEASURE, SCR_RESOURCE_SERVING_CHANNEL); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| pMeasurementMgr->Connected = TI_FALSE; |
| |
| return TI_OK; |
| } |
| |
| |
| |
| /** |
| * Called if the Measurement Manager module is disabled while we are |
| * waiting for a response from the SCR. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acDisable_fromWaitForSCR(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| setDefaultProbeReqTemplate (pMeasurementMgr->hSiteMgr); |
| |
| /* Release the SCR */ |
| scr_clientComplete(pMeasurementMgr->hScr, SCR_CID_XCC_MEASURE, SCR_RESOURCE_SERVING_CHANNEL); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| pMeasurementMgr->Enabled = TI_FALSE; |
| |
| return TI_OK; |
| } |
| |
| |
| |
| /** |
| * Called if a frame is received after we requested the SCR for another frame. |
| * In this case the older frame is discarded and the new frame is processed. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acFrameReceived_fromWaitForSCR(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| setDefaultProbeReqTemplate (pMeasurementMgr->hSiteMgr); |
| |
| /* Release the SCR */ |
| scr_clientComplete(pMeasurementMgr->hScr, SCR_CID_XCC_MEASURE, SCR_RESOURCE_SERVING_CHANNEL); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| /* Process New Frame */ |
| return measurementMgrSM_acFrameReceived_fromIdle(pData); |
| } |
| |
| |
| |
| /** |
| * Called if the SCR callbacked with a response other than RUN. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acAbort_fromWaitForSCR(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| setDefaultProbeReqTemplate (pMeasurementMgr->hSiteMgr); |
| |
| /* Release the SCR */ |
| scr_clientComplete(pMeasurementMgr->hScr, SCR_CID_XCC_MEASURE, SCR_RESOURCE_SERVING_CHANNEL); |
| |
| /* Build a reject report */ |
| measurementMgr_rejectPendingRequests(pMeasurementMgr, MSR_REJECT_SCR_UNAVAILABLE); |
| |
| /* Clear Measurement fields */ |
| pMeasurementMgr->sendReportAndCleanObj(pMeasurementMgr); |
| |
| return TI_OK; |
| } |
| |
| |
| |
| /** |
| * Called when the SCR callbacks with a RUN response or if the SCR |
| * returned a RUN response when we requested it. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acStartMeasurement(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| /* Cryptic: the first struct is the requestHandler request while */ |
| /* the second one is the measurementSRV request */ |
| MeasurementRequest_t * pRequestArr[MAX_NUM_REQ]; |
| TMeasurementRequest request; |
| paramInfo_t *pParam; |
| TI_UINT8 numOfRequestsInParallel; |
| TI_UINT8 requestIndex; |
| TI_UINT32 timePassed; |
| TI_BOOL requestedBeaconMeasurement= TI_FALSE; |
| TI_STATUS status; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Starting Measurement operation\n"); |
| |
| pParam = (paramInfo_t *)os_memoryAlloc(pMeasurementMgr->hOs, sizeof(paramInfo_t)); |
| if (!pParam) |
| { |
| return TI_NOK; |
| } |
| |
| request.channel = pMeasurementMgr->measuredChannelID; |
| request.startTime = 0; /* ignored by MeasurementSRV for now - for .11k */ |
| request.numberOfTypes = 0; |
| |
| TRACE1(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Measured Channel = %d\n", pMeasurementMgr->measuredChannelID); |
| |
| pParam->paramType = REGULATORY_DOMAIN_GET_SCAN_CAPABILITIES; |
| pParam->content.channelCapabilityReq.channelNum = pMeasurementMgr->measuredChannelID; |
| pParam->content.channelCapabilityReq.scanOption = ACTIVE_SCANNING; |
| |
| if (pMeasurementMgr->measuredChannelID <= MAX_CHANNEL_IN_BAND_2_4) |
| { |
| request.band = RADIO_BAND_2_4_GHZ; |
| pParam->content.channelCapabilityReq.band = RADIO_BAND_2_4_GHZ; |
| } |
| else |
| { |
| request.band = RADIO_BAND_5_0_GHZ; |
| pParam->content.channelCapabilityReq.band = RADIO_BAND_5_0_GHZ; |
| } |
| |
| regulatoryDomain_getParam(pMeasurementMgr->hRegulatoryDomain, pParam); |
| |
| request.txPowerDbm = pParam->content.channelCapabilityRet.maxTxPowerDbm; |
| |
| request.eTag = SCAN_RESULT_TAG_MEASUREMENT; |
| os_memoryFree(pMeasurementMgr->hOs, pParam, sizeof(paramInfo_t)); |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Querying Request Handler for the next request in the queue\n"); |
| |
| /* Getting the next request/requests from the request handler */ |
| status = requestHandler_getNextReq(pMeasurementMgr->hRequestH, TI_TRUE, pRequestArr, |
| &numOfRequestsInParallel); |
| |
| if (status != TI_OK) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_ERROR, ": Failed getting next request from Request Handler\n"); |
| return measurementMgrSM_event((TI_UINT8 *) &(pMeasurementMgr->currentState), |
| MEASUREMENTMGR_EVENT_COMPLETE, pMeasurementMgr); |
| } |
| |
| /* Save the number of requests in parallel so that once the */ |
| /* measurement operation ends we can get rid of this amount of requests */ |
| /* from the requestHandler */ |
| pMeasurementMgr->currentNumOfRequestsInParallel = numOfRequestsInParallel; |
| |
| for (requestIndex = 0; requestIndex < numOfRequestsInParallel; requestIndex++) |
| { |
| if (pRequestArr[requestIndex]->Type == MSR_TYPE_BEACON_MEASUREMENT) |
| { |
| requestedBeaconMeasurement = TI_TRUE; |
| |
| if (pRequestArr[requestIndex]->ScanMode == MSR_SCAN_MODE_BEACON_TABLE) |
| { |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Beacon Table request encountered, building report now\n"); |
| |
| /* building Report for beacon table request */ |
| pMeasurementMgr->buildReport(pMeasurementMgr, *pRequestArr[requestIndex], NULL); |
| |
| continue; |
| } |
| } |
| |
| /* save the request so we can reference it when results arrive */ |
| pMeasurementMgr->currentRequest[request.numberOfTypes] = pRequestArr[requestIndex]; |
| |
| /* add the measurement type to the request's list */ |
| request.msrTypes[request.numberOfTypes].duration = pRequestArr[requestIndex]->DurationTime; |
| request.msrTypes[request.numberOfTypes].scanMode = pRequestArr[requestIndex]->ScanMode; |
| request.msrTypes[request.numberOfTypes].msrType = pRequestArr[requestIndex]->Type; |
| |
| TRACE3(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ":\n\nMeasurement Request #%d Details: Type = %d, Duration = %d\n\n", request.numberOfTypes+1, request.msrTypes[request.numberOfTypes].msrType, request.msrTypes[request.numberOfTypes].duration); |
| |
| request.numberOfTypes++; |
| } |
| |
| if (requestedBeaconMeasurement == TI_TRUE) |
| { |
| /* build a probe request template and send it to the HAL */ |
| TSetTemplate templateStruct; |
| probeReqTemplate_t probeReqTemplate; |
| TSsid broadcastSSID; |
| |
| templateStruct.ptr = (TI_UINT8 *) &probeReqTemplate; |
| templateStruct.type = PROBE_REQUEST_TEMPLATE; |
| templateStruct.eBand = request.band; |
| templateStruct.uRateMask = RATE_MASK_UNSPECIFIED; |
| broadcastSSID.len = 0; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Sending probe request template...\n"); |
| |
| buildProbeReqTemplate( pMeasurementMgr->hSiteMgr, &templateStruct, &broadcastSSID, request.band ); |
| #ifdef XCC_MODULE_INCLUDED |
| { /* Insert Radio Mngt Capability IE according XCC4*/ |
| TI_UINT32 len = 0; |
| measurementMgr_radioMngtCapabilityBuild (pMeasurementMgr, |
| templateStruct.ptr + templateStruct.len, |
| (TI_UINT8*)&len); |
| templateStruct.len += len; |
| } |
| #endif |
| |
| TWD_CmdTemplate (pMeasurementMgr->hTWD, &templateStruct, NULL, NULL); |
| } |
| |
| /* Check if the maximum time to wait for the measurement request to */ |
| /* finish has already passed */ |
| timePassed = os_timeStampMs(pMeasurementMgr->hOs) - pMeasurementMgr->currentRequestStartTime; |
| if (timePassed > MSR_START_MAX_DELAY) |
| { |
| TRACE2(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Maximum delay to perform measurement operation has passed (%d / %d)\n", MSR_START_MAX_DELAY, (os_timeStampMs(pMeasurementMgr->hOs) - pMeasurementMgr->currentRequestStartTime)); |
| |
| pMeasurementMgr->buildRejectReport(pMeasurementMgr, pRequestArr, numOfRequestsInParallel, MSR_REJECT_MAX_DELAY_PASSED); |
| return measurementMgrSM_event((TI_UINT8 *) &(pMeasurementMgr->currentState), |
| MEASUREMENTMGR_EVENT_COMPLETE, pMeasurementMgr); |
| } |
| |
| /* set the measurement scan executed flag to TRUE */ |
| pMeasurementMgr->bMeasurementScanExecuted = TI_TRUE; |
| |
| /* Yalla, start measuring */ |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Finished preparing request. Handing over to MeasurementSRV...\n"); |
| |
| TWD_StartMeasurement (pMeasurementMgr->hTWD, |
| &request, |
| MSR_START_MAX_DELAY - timePassed, |
| NULL, NULL, |
| measurementMgr_MeasurementCompleteCB, |
| pMeasurementMgr); |
| return TI_OK; |
| } |
| |
| |
| |
| |
| |
| |
| /********************************************************************************/ |
| /* MEASURING State Actions */ |
| /********************************************************************************/ |
| |
| |
| static TI_STATUS measurementMgrSM_acDisconnected_fromMeasuring(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| setDefaultProbeReqTemplate (pMeasurementMgr->hSiteMgr); |
| |
| /* release the SCR */ |
| scr_clientComplete(pMeasurementMgr->hScr, SCR_CID_XCC_MEASURE, SCR_RESOURCE_SERVING_CHANNEL); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| pMeasurementMgr->Connected = TI_FALSE; |
| |
| return TI_OK; |
| } |
| |
| |
| |
| static TI_STATUS measurementMgrSM_acDisable_fromMeasuring(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| setDefaultProbeReqTemplate (pMeasurementMgr->hSiteMgr); |
| |
| /* release the SCR */ |
| scr_clientComplete(pMeasurementMgr->hScr, SCR_CID_XCC_MEASURE, SCR_RESOURCE_SERVING_CHANNEL); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| pMeasurementMgr->Enabled = TI_FALSE; |
| |
| return TI_OK; |
| } |
| |
| |
| |
| static TI_STATUS measurementMgrSM_acFrameReceived_fromMeasuring(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| setDefaultProbeReqTemplate (pMeasurementMgr->hSiteMgr); |
| |
| /* release the SCR */ |
| scr_clientComplete(pMeasurementMgr->hScr, SCR_CID_XCC_MEASURE, SCR_RESOURCE_SERVING_CHANNEL); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| /* Process New Frame */ |
| return measurementMgrSM_acFrameReceived_fromIdle(pData); |
| } |
| |
| |
| |
| static TI_STATUS measurementMgrSM_acAbort_fromMeasuring(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| setDefaultProbeReqTemplate (pMeasurementMgr->hSiteMgr); |
| |
| /* release the SCR */ |
| scr_clientComplete(pMeasurementMgr->hScr, SCR_CID_XCC_MEASURE, SCR_RESOURCE_SERVING_CHANNEL); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| TWD_StopMeasurement (pMeasurementMgr->hTWD, TI_TRUE ,NULL, NULL); |
| |
| return TI_OK; |
| } |
| |
| |
| |
| /** |
| * Called when we finished a measurement request. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acMeasurementComplete(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| requestHandler_t * pRequestH = (requestHandler_t *) pMeasurementMgr->hRequestH; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Completing measurement operation and resuming normal behavior\n"); |
| |
| /* advance the activeRequestID variable to get rid of the */ |
| /* measurement requests we've already executed */ |
| TRACE2(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Increasing activeRequestID from %d to %d.\n", pRequestH->activeRequestID, pRequestH->activeRequestID + pMeasurementMgr->currentNumOfRequestsInParallel); |
| |
| pRequestH->activeRequestID += pMeasurementMgr->currentNumOfRequestsInParallel; |
| |
| setDefaultProbeReqTemplate (pMeasurementMgr->hSiteMgr); |
| |
| /* move the driver result table to stable state and clear it */ |
| sme_MeansurementScanResult (pMeasurementMgr->hSme, SCAN_CRS_SCAN_COMPLETE_OK, NULL); |
| |
| /* release the SCR */ |
| scr_clientComplete(pMeasurementMgr->hScr, SCR_CID_XCC_MEASURE, SCR_RESOURCE_SERVING_CHANNEL); |
| |
| /* Process New Frame */ |
| return measurementMgr_activateNextRequest(pData); |
| } |
| |
| |
| |
| /** |
| * Called when a firmware reset has been detected. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acFirmwareReset(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Firmware Reset!!\n"); |
| |
| setDefaultProbeReqTemplate (pMeasurementMgr->hSiteMgr); |
| |
| /* release the SCR */ |
| scr_clientComplete(pMeasurementMgr->hScr, SCR_CID_XCC_MEASURE, SCR_RESOURCE_SERVING_CHANNEL); |
| |
| /* Clear Measurement fields */ |
| measurementMgrSM_resetParams(pMeasurementMgr); |
| |
| return TI_OK; |
| } |
| |
| |
| |
| |
| |
| |
| |
| /********************************************************************************/ |
| /* Miscellaneous State Actions */ |
| /********************************************************************************/ |
| |
| /** |
| * Called when an unexpected event has been triggered. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acUnexpected(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Entered when state is \n"); |
| |
| return TI_OK; |
| } |
| |
| /** |
| * A do nothing action. |
| * |
| * @date 05-Jan-2006 |
| */ |
| static TI_STATUS measurementMgrSM_acNop(void * pData) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *) pData; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Entered when state is \n"); |
| |
| return TI_OK; |
| } |
| |
| |
| |
| |
| |
| |
| |
| |
| /********************************************************************************/ |
| /* Internal Functions Prototypes */ |
| /********************************************************************************/ |
| |
| |
| static void measurementMgrSM_resetParams(measurementMgr_t *pMeasurementMgr) |
| { |
| /* clear the waiting requests */ |
| requestHandler_clearRequests(pMeasurementMgr->hRequestH); |
| |
| /* clearing reports data base */ |
| #ifdef XCC_MODULE_INCLUDED |
| os_memoryZero(pMeasurementMgr->hOs,&(pMeasurementMgr->XCCFrameReport), |
| sizeof(RM_report_frame_t)); |
| #endif |
| os_memoryZero(pMeasurementMgr->hOs,&(pMeasurementMgr->dot11hFrameReport), |
| sizeof(MeasurementReportFrame_t)); |
| |
| pMeasurementMgr->frameLength = 0; |
| pMeasurementMgr->nextEmptySpaceInReport = 0; |
| pMeasurementMgr->measuredChannelID = 0; |
| pMeasurementMgr->currentFrameType = MSR_FRAME_TYPE_NO_ACTIVE; |
| } |
| |
| |
| |
| /** |
| * The callback called when the activation delay timer has ended. |
| * |
| * @param hMeasurementMgr - A handle to the Measurement Manager module. |
| * @param bTwdInitOccured - Indicates if TWDriver recovery occured since timer started |
| * |
| * @date 01-Jan-2006 |
| */ |
| static void measurementMgrSM_uponActivationDelayTimeout (TI_HANDLE hMeasurementMgr, TI_BOOL bTwdInitOccured) |
| { |
| measurementMgr_t * pMeasurementMgr = (measurementMgr_t *)hMeasurementMgr; |
| |
| TRACE0(pMeasurementMgr->hReport, REPORT_SEVERITY_INFORMATION, ": Activation delay timeout callback entered\n"); |
| |
| measurementMgr_activateNextRequest (pMeasurementMgr); |
| } |
| |